{"id":1567,"date":"2025-06-03T13:34:22","date_gmt":"2025-06-03T06:34:22","guid":{"rendered":"https:\/\/htiscientific.vn\/?p=1567"},"modified":"2025-06-06T12:12:50","modified_gmt":"2025-06-06T05:12:50","slug":"phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max","status":"publish","type":"post","link":"https:\/\/htiscientific.vn\/en\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/","title":{"rendered":"Determination of trace elements in graphite with Avio 220 Max ICP-OES"},"content":{"rendered":"<h1 style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Rapid Determination<\/strong><strong>\u00a0of 13 Trace Elements\u00a0<\/strong><strong>in\u00a0<\/strong><strong>Graphite with the  Avio 220 Max ICP-OES<\/strong><\/span><\/h1>\n<h2 style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Gi\u1edbi thi\u1ec7u<\/strong><\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">The anode is one of the core components of lithium-ion batteries; its function is energy storage and release, thereby affecting the cycling performance of the battery. Although anodes can be made from different materials, the most commonly used is artificial graphite due to its low price, long lifetime, and high storage capacity. China Standard GB\/T 24533-20191 specifies that the trace element limit in Grade \u2160 artificial graphite used for anodes is &lt; 5 mg\/ kg, and that the iron and sulfur content must be less than 20 mg\/kg, as shown in Table 1.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-medium wp-image-7084 aligncenter\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133653.png\" alt=\"\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Table 1. GB\/T 24533-2019 Impurity Levels in Grade \u2160 Artificial Graphite\u00a0<\/strong><strong>\u2160<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">Appendix H of GB\/T 24533-2019 recommends microwave digestion for sample preparation, but given the difficulty of digesting graphite, this method is acid-intensive, cumbersome, requires a long digestion time, and is unsuitable for batch samples.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">In this work, an alternate sample preparation strategy is explored which uses less acid, simplifies  the sample preparation process, and can easily be scaled to accommodate large numbers  of samples. The Avio\u00ae 220 Max hybrid simultaneous ICP-OES is  used to measure 13 elements  from both microwave digestion  and the alternate sample preparation to compare both sample-preparation techniques.<\/span><\/p>\n<h2 style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Experimental<\/strong><\/span><\/h2>\n<h3 style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Samples and Sample Preparation<\/strong><\/span><\/h3>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Sample Preparation Block Leaching<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">A 0.5 g quantity of two unknown graphite samples (Graphite A, Graphite B) was placed in 50 mL DigiTUBES\u00ae, followed by 5 mL aqua regia. The tubes were loosely capped and heated at 120 \u00b0C for 60 minutes in a Sample Preparation Block. After heating, the tubes were cooled to room temperature, brought to 50 mL with deionized water, and centrifuged for 10 minutes at 9000 rpm. To check for contamination, preparation blanks were prepared in the same way, but without the addition of graphite. Analyte spikes at 0.1 mg\/L were added to the samples prior to the addition of aqua regia.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Microwave Sample Preparation<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">A 0.5 g quantity of two unknown graphite samples was placed in microwave digestion vessels, followed by 10 mL of aqua regia. The vessels were left uncapped for 15 minutes to allow any early reactions to occur before being sealed. The samples were digested at 220 \u00b0C for 30 minutes, then allowed to cool to room temperature before the contents were transferred to 50 mL autosampler tubes and brought to 50 mL with deionized water for analysis. Because the graphite could not be completely digested, the samples were centrifuged to separate the solids from the acid. Sample preparation blanks were prepared in the same manner as the samples, but without the addition of graphite. Analyte spikes at 0.1 mg\/L were added to the samples prior to the addition of aqua regia.<\/span><\/p>\n<h3 style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Instrumental Conditions<\/strong><\/span><\/h3>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">All analyses were performed on an Avio 220 Max hybrid simultaneous ICP-OES using the conditions in Table 2 and the elements and wavelengths in Table 3.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-medium wp-image-7102 aligncenter\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133707.png\" alt=\"\" \/>\u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Table 2<\/strong><strong>. Avio 220 Max ICP-OES Instrumental Parameters.\u00a0 \u00a0<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">The Avio 220\u2019s unique optical system 2,3 provides excellent sensitivity, allowing for accurate determinations at low concentrations, which is important when assessing impurities. Another benefit of the high sensitivity is the ability to use radial plasma view for the analysis. With the high level of dissolved solids in these samples (10%), radial plasma view provides the advantage of reduced matrix effects in the plasma. As a result, all measurements were made against external calibration curves, with standards prepared in 5% nitric acid (v\/v) at the concentrations in Table 4. The calibration blank was 5% nitric acid.<\/span><\/p>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td style=\"width: 50%;\">\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><strong>Table 3. Elements and Wavelengths.<\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1654\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133718.png\" alt=\"\" width=\"349\" height=\"649\" srcset=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133718.png 259w, https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133718-167x300.png 167w, https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133718-7x12.png 7w\" sizes=\"auto, (max-width: 349px) 100vw, 349px\" \/><\/td>\n<td style=\"width: 50%;\">\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><strong>Table 4. Calibration Standards.<\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1655\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133725.png\" alt=\"\" width=\"350\" height=\"342\" srcset=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133725.png 260w, https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133725-12x12.png 12w, https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133725-75x75.png 75w, https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133725-100x100.png 100w\" sizes=\"auto, (max-width: 350px) 100vw, 350px\" \/><\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Results and Discussion<\/strong><\/span><\/h3>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">During method development, several spectral lines for each element were evaluated, and the selected lines (Table 3) provided the highest signal-to-background ratios and were interference-free. Calibration curves for all analytes produced correlation coefficients great than 0.9999, as shown in Table 5, along with example curves in Figure 1.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-medium wp-image-7096 aligncenter\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133735.png\" alt=\"\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Table\u00a0<\/strong><strong>5. Correlation Coefficients for Calibration Curves for Each Element.<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-medium wp-image-7107 aligncenter\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133744.png\" alt=\"\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Figure 1. Example calibration curves of selected elements.<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">Next, detection limits in solution were determined by 11 measurements of a sample preparation blank prepared with the Sample Preparation Block and multiplying the standard deviation by 3. To account for a 100x dilution factor and establish method detection limits, the solution detection limits were multiplied by 100. Both solution and solid detection limits are shown in Table 6 and are sufficiently low to meet the requirements of GB\/T 24533-2019.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-medium wp-image-7094 aligncenter\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133753.png\" alt=\"\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Table\u00a0<\/strong><strong>6. Detection Limits in Solution and Solid.<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">With the detection limits established, the graphite samples from the rapid leach preparation were analyzed. As shown in Table 7, both graphite samples meet the specification of Grade \u2160 artificial graphite as defined in GB\/T 24533-2019.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-medium wp-image-7092 aligncenter\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133802.png\" alt=\"\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Table\u00a0<\/strong><strong>7. Results and Spike Recoveries from Graphite with Rapid Leaching.<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">To assess accuracy, samples were spiked at 0.1 ppm of the analytes before the leach procedure and analyzed after the leach. The spike recoveries were all within 10% of their true values for both samples, as shown in Table 7.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">To evaluate the consistency of the leach procedure with the Sample Preparation Block and Avio 220 Max ICP-OES, Graphite B was prepared with a 0.1 mg\/L spike and analyzed 11 times. The RSDs of the 11 measurements appear in  Table 8 and are all less than 1%, with the exception of mercury, demonstrating the consistency and accuracy of  both the Sample Preparation Block leach procedure and the Avio 220 Max.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-medium wp-image-7090 aligncenter\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133809.png\" alt=\"\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Table\u00a0<\/strong><strong>8. Repeatability of Rapid Leach Method.<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>RSDs of 11 Preparations and Analyses of Graphite B Spiked with 0.1 mg\/L.<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">The Sample Preparation Block leaching method was compared to the established microwave digestion by preparing the graphite samples by both methods and analyzing. As shown in Table 9, the results compare favorably, with deviations of less than 10% between the results from both sample preparation methods. Interestingly, the higher temperature used in the microwave  (220 \u00b0C vs. 120 \u00b0C in the Sample Preparation Block) does not yield higher concentrations, which demonstrates that all the metals are leached at 120 \u00b0C.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">Although the Sample Preparation Block leach time (60 minutes) is longer than the microwave time (30 minutes), the Sample Preparation Block method can provide higher sample throughput when considering the complete sample preparation:<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li><span style=\"color: #000000;\">Time to seal the microwave vessels<\/span><\/li>\n<li><span style=\"color: #000000;\">Time to cool the samples to room temperature (120 \u00b0C via leaching vs. 220 \u00b0C from microwave digestion) before bringing to final volume<\/span><\/li>\n<li><span style=\"color: #000000;\">Necessity to transfer the digested sample from the microwave vessel to autosampler tubes for analysis<\/span><\/li>\n<li><span style=\"color: #000000;\">Time to wash the microwave vessels<\/span><\/li>\n<li><span style=\"color: #000000;\">Ability to easily accommodate a large number of samples<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">An additional benefit of the Sample Preparation Block leach method is that it uses half the amount of acid (5 mL vs. 10 mL).<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-medium wp-image-7088 aligncenter\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133819.png\" alt=\"\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Table 9. Results Comparison: Sample Preparation Block and Microwave.<\/strong><\/span><\/p>\n<h2 style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Conclusion<\/strong><\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">This work has demonstrated a simplified, alternative sample preparation scheme to accommodate the determination of contaminants in graphite in accordance with Chinese standard GB\/T 24533-2019. By using a leaching procedure with a Sample Preparation Block, sample preparation is simplified despite using less acid and having the ability to prepare a larger number of samples. The leaching procedure was verified by comparing analytical results attained on the Avio 220 Max hybrid simultaneous ICP-OES to those from the conventional microwave procedure. The advantages of the Avio 220 Max include high sensitivity and robustness, allowing for accurate analyses at low concentrations. The combination of rapid leaching with analysis using the Avio 220 Max ICP-OES is ideal for the determination of impurities in graphite to meet the needs of the lithium-ion battery market.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>Consumables Used<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-medium wp-image-7086 aligncenter\" src=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/screenshot-2025-06-06-133826.png\" alt=\"\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><strong>\u00a0<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><em><strong>References:<\/strong><\/em><\/span><\/p>\n<ol style=\"text-align: justify;\">\n<li><span style=\"color: #000000;\"><em>GB\/T 24533-2019 \u201cGraphite Anode Materials for LithiumIon Batteries\u201d, https:\/\/www.chinesestandard.net\/PDF.aspx\/ GBT24533-2019.<\/em><\/span><\/li>\n<li><span style=\"color: #000000;\"><em>\u201cThe Avio 220 Max ICP-OES: A Unique Double-Monochromator Optical System\u201d, Technical Note, PerkinElmer, 2020.<\/em><\/span><\/li>\n<li><span style=\"color: #000000;\"><em>\u201cAvio 220 Max ICP-OES Custom-Designed Solid-State Detector with Hybrid Simultaneous Analysis\u201d, Technical Note, PerkinElmer, 2020.<\/em><\/span><\/li>\n<\/ol>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">Learn more: <a href=\"https:\/\/perkinelmer.widen.net\/content\/ulshfxm9h7\/pdf\/app-rapid-determination-of-13-trace-elements-in-graphite-with-the-avio-220-max-icp-oes.pdf?u=3ezgsz\">https:\/\/perkinelmer\/app-rapid-determination-of-13-trace-elements-in-graphite-with-the-avio-220-max-icp-oes<\/a><\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>\u0110\u1ecbnh l\u01b0\u1ee3ng\u00a0nhanh 13 nguy\u00ean t\u1ed1\u00a0l\u01b0\u1ee3ng\u00a0v\u1ebft trong than ch\u00ec b\u1eb1ng Avio 220 Max ICP-OES Gi\u1edbi thi\u1ec7u C\u1ef1c d\u01b0\u01a1ng (anode) l\u00e0 m\u1ed9t trong nh\u1eefng th\u00e0nh ph\u1ea7n c\u1ed1t l\u00f5i c\u1ee7a pin lithium-ion; ch\u1ee9c n\u0103ng c\u1ee7a n\u00f3 l\u00e0 l\u01b0u tr\u1eef v\u00e0 gi\u1ea3i ph\u00f3ng n\u0103ng l\u01b0\u1ee3ng, do \u0111\u00f3 \u1ea3nh h\u01b0\u1edfng \u0111\u1ebfn hi\u1ec7u su\u1ea5t chu k\u1ef3&#8230;<\/p>","protected":false},"author":2,"featured_media":1569,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[17,1],"tags":[],"class_list":["post-1567","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-tin-tuc"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max - HTI Scientific<\/title>\n<meta name=\"description\" content=\"H\u1ec7 th\u1ed1ng quang h\u1ecdc \u0111\u1ed9c \u0111\u00e1o c\u1ee7a Avio 220 cung c\u1ea5p \u0111\u1ed9 nh\u1ea1y tuy\u1ec7t v\u1eddi, \u0111\u1ecbnh l\u01b0\u1ee3ng ch\u00ednh x\u00e1c c\u00e1c m\u1eabu n\u1ed3ng \u0111\u1ed9 th\u1ea5p, gi\u00fap \u0111\u00e1nh gi\u00e1 t\u1ea1p ch\u1ea5t..\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/htiscientific.vn\/en\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max - HTI Scientific\" \/>\n<meta property=\"og:description\" content=\"H\u1ec7 th\u1ed1ng quang h\u1ecdc \u0111\u1ed9c \u0111\u00e1o c\u1ee7a Avio 220 cung c\u1ea5p \u0111\u1ed9 nh\u1ea1y tuy\u1ec7t v\u1eddi, \u0111\u1ecbnh l\u01b0\u1ee3ng ch\u00ednh x\u00e1c c\u00e1c m\u1eabu n\u1ed3ng \u0111\u1ed9 th\u1ea5p, gi\u00fap \u0111\u00e1nh gi\u00e1 t\u1ea1p ch\u1ea5t..\" \/>\n<meta property=\"og:url\" content=\"https:\/\/htiscientific.vn\/en\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/\" \/>\n<meta property=\"og:site_name\" content=\"HTI Scientific\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/htiscientific.vn\" \/>\n<meta property=\"article:published_time\" content=\"2025-06-03T06:34:22+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-06T05:12:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"650\" \/>\n\t<meta property=\"og:image:height\" content=\"413\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"HTI\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"HTI\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/\"},\"author\":{\"name\":\"HTI\",\"@id\":\"https:\/\/htiscientific.vn\/#\/schema\/person\/85d5206dec7b9b8c2207d4148afbe9db\"},\"headline\":\"Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max\",\"datePublished\":\"2025-06-03T06:34:22+00:00\",\"dateModified\":\"2025-06-06T05:12:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/\"},\"wordCount\":2541,\"publisher\":{\"@id\":\"https:\/\/htiscientific.vn\/#organization\"},\"image\":{\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg\",\"articleSection\":[\"Blog\",\"Tin t\u1ee9c\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/\",\"url\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/\",\"name\":\"Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max - HTI Scientific\",\"isPartOf\":{\"@id\":\"https:\/\/htiscientific.vn\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg\",\"datePublished\":\"2025-06-03T06:34:22+00:00\",\"dateModified\":\"2025-06-06T05:12:50+00:00\",\"description\":\"H\u1ec7 th\u1ed1ng quang h\u1ecdc \u0111\u1ed9c \u0111\u00e1o c\u1ee7a Avio 220 cung c\u1ea5p \u0111\u1ed9 nh\u1ea1y tuy\u1ec7t v\u1eddi, \u0111\u1ecbnh l\u01b0\u1ee3ng ch\u00ednh x\u00e1c c\u00e1c m\u1eabu n\u1ed3ng \u0111\u1ed9 th\u1ea5p, gi\u00fap \u0111\u00e1nh gi\u00e1 t\u1ea1p ch\u1ea5t..\",\"breadcrumb\":{\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#primaryimage\",\"url\":\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg\",\"contentUrl\":\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg\",\"width\":650,\"height\":413,\"caption\":\"than-chi\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Trang ch\u1ee7\",\"item\":\"https:\/\/htiscientific.vn\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Tin t\u1ee9c\",\"item\":\"https:\/\/htiscientific.vn\/chuyen-muc\/tin-tuc\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Blog\",\"item\":\"https:\/\/htiscientific.vn\/chuyen-muc\/tin-tuc\/blog\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/htiscientific.vn\/#website\",\"url\":\"https:\/\/htiscientific.vn\/\",\"name\":\"HTI Scientific\",\"description\":\"HTI Scientific\",\"publisher\":{\"@id\":\"https:\/\/htiscientific.vn\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/htiscientific.vn\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/htiscientific.vn\/#organization\",\"name\":\"HTI Scientific\",\"alternateName\":\"HTI Scientific\",\"url\":\"https:\/\/htiscientific.vn\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/htiscientific.vn\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/03\/ava-hti-copy.jpg\",\"contentUrl\":\"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/03\/ava-hti-copy.jpg\",\"width\":700,\"height\":450,\"caption\":\"HTI Scientific\"},\"image\":{\"@id\":\"https:\/\/htiscientific.vn\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/htiscientific.vn\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/htiscientific.vn\/#\/schema\/person\/85d5206dec7b9b8c2207d4148afbe9db\",\"name\":\"HTI\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/htiscientific.vn\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/08122fa259061ceb72185bc2d8eee0381902bba58a9c68ff15a511e69c64ea97?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/08122fa259061ceb72185bc2d8eee0381902bba58a9c68ff15a511e69c64ea97?s=96&d=mm&r=g\",\"caption\":\"HTI\"},\"sameAs\":[\"https:\/\/htiscientific.vn\/\"],\"url\":\"https:\/\/htiscientific.vn\/en\/author\/hti-admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max - HTI Scientific","description":"H\u1ec7 th\u1ed1ng quang h\u1ecdc \u0111\u1ed9c \u0111\u00e1o c\u1ee7a Avio 220 cung c\u1ea5p \u0111\u1ed9 nh\u1ea1y tuy\u1ec7t v\u1eddi, \u0111\u1ecbnh l\u01b0\u1ee3ng ch\u00ednh x\u00e1c c\u00e1c m\u1eabu n\u1ed3ng \u0111\u1ed9 th\u1ea5p, gi\u00fap \u0111\u00e1nh gi\u00e1 t\u1ea1p ch\u1ea5t..","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/htiscientific.vn\/en\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/","og_locale":"en_US","og_type":"article","og_title":"Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max - HTI Scientific","og_description":"H\u1ec7 th\u1ed1ng quang h\u1ecdc \u0111\u1ed9c \u0111\u00e1o c\u1ee7a Avio 220 cung c\u1ea5p \u0111\u1ed9 nh\u1ea1y tuy\u1ec7t v\u1eddi, \u0111\u1ecbnh l\u01b0\u1ee3ng ch\u00ednh x\u00e1c c\u00e1c m\u1eabu n\u1ed3ng \u0111\u1ed9 th\u1ea5p, gi\u00fap \u0111\u00e1nh gi\u00e1 t\u1ea1p ch\u1ea5t..","og_url":"https:\/\/htiscientific.vn\/en\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/","og_site_name":"HTI Scientific","article_publisher":"https:\/\/www.facebook.com\/htiscientific.vn","article_published_time":"2025-06-03T06:34:22+00:00","article_modified_time":"2025-06-06T05:12:50+00:00","og_image":[{"width":650,"height":413,"url":"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg","type":"image\/jpeg"}],"author":"HTI","twitter_card":"summary_large_image","twitter_misc":{"Written by":"HTI","Est. reading time":"12 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#article","isPartOf":{"@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/"},"author":{"name":"HTI","@id":"https:\/\/htiscientific.vn\/#\/schema\/person\/85d5206dec7b9b8c2207d4148afbe9db"},"headline":"Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max","datePublished":"2025-06-03T06:34:22+00:00","dateModified":"2025-06-06T05:12:50+00:00","mainEntityOfPage":{"@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/"},"wordCount":2541,"publisher":{"@id":"https:\/\/htiscientific.vn\/#organization"},"image":{"@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#primaryimage"},"thumbnailUrl":"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg","articleSection":["Blog","Tin t\u1ee9c"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/","url":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/","name":"Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max - HTI Scientific","isPartOf":{"@id":"https:\/\/htiscientific.vn\/#website"},"primaryImageOfPage":{"@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#primaryimage"},"image":{"@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#primaryimage"},"thumbnailUrl":"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg","datePublished":"2025-06-03T06:34:22+00:00","dateModified":"2025-06-06T05:12:50+00:00","description":"H\u1ec7 th\u1ed1ng quang h\u1ecdc \u0111\u1ed9c \u0111\u00e1o c\u1ee7a Avio 220 cung c\u1ea5p \u0111\u1ed9 nh\u1ea1y tuy\u1ec7t v\u1eddi, \u0111\u1ecbnh l\u01b0\u1ee3ng ch\u00ednh x\u00e1c c\u00e1c m\u1eabu n\u1ed3ng \u0111\u1ed9 th\u1ea5p, gi\u00fap \u0111\u00e1nh gi\u00e1 t\u1ea1p ch\u1ea5t..","breadcrumb":{"@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#primaryimage","url":"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg","contentUrl":"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/06\/than-da.jpg","width":650,"height":413,"caption":"than-chi"},{"@type":"BreadcrumbList","@id":"https:\/\/htiscientific.vn\/phan-tich-nguyen-to-vi-luong-trong-than-chi-su-dung-icp-oes-avio-220-max\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Trang ch\u1ee7","item":"https:\/\/htiscientific.vn\/"},{"@type":"ListItem","position":2,"name":"Tin t\u1ee9c","item":"https:\/\/htiscientific.vn\/chuyen-muc\/tin-tuc\/"},{"@type":"ListItem","position":3,"name":"Blog","item":"https:\/\/htiscientific.vn\/chuyen-muc\/tin-tuc\/blog\/"},{"@type":"ListItem","position":4,"name":"Ph\u00e2n t\u00edch nguy\u00ean t\u1ed1 vi l\u01b0\u1ee3ng trong than ch\u00ec s\u1eed d\u1ee5ng ICP-OES Avio 220 Max"}]},{"@type":"WebSite","@id":"https:\/\/htiscientific.vn\/#website","url":"https:\/\/htiscientific.vn\/","name":"HTI Scientific","description":"HTI Scientific","publisher":{"@id":"https:\/\/htiscientific.vn\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/htiscientific.vn\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/htiscientific.vn\/#organization","name":"HTI Scientific","alternateName":"HTI Scientific","url":"https:\/\/htiscientific.vn\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/htiscientific.vn\/#\/schema\/logo\/image\/","url":"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/03\/ava-hti-copy.jpg","contentUrl":"https:\/\/htiscientific.vn\/wp-content\/uploads\/2025\/03\/ava-hti-copy.jpg","width":700,"height":450,"caption":"HTI Scientific"},"image":{"@id":"https:\/\/htiscientific.vn\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/htiscientific.vn"]},{"@type":"Person","@id":"https:\/\/htiscientific.vn\/#\/schema\/person\/85d5206dec7b9b8c2207d4148afbe9db","name":"HTI","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/htiscientific.vn\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/08122fa259061ceb72185bc2d8eee0381902bba58a9c68ff15a511e69c64ea97?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/08122fa259061ceb72185bc2d8eee0381902bba58a9c68ff15a511e69c64ea97?s=96&d=mm&r=g","caption":"HTI"},"sameAs":["https:\/\/htiscientific.vn\/"],"url":"https:\/\/htiscientific.vn\/en\/author\/hti-admin\/"}]}},"_links":{"self":[{"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/posts\/1567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/comments?post=1567"}],"version-history":[{"count":7,"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/posts\/1567\/revisions"}],"predecessor-version":[{"id":1653,"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/posts\/1567\/revisions\/1653"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/media\/1569"}],"wp:attachment":[{"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/media?parent=1567"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/categories?post=1567"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/htiscientific.vn\/en\/wp-json\/wp\/v2\/tags?post=1567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}